Q-Temp

Non-eugenol temporary resin cement with fluoride, potassium nitrate and chlorhexidine
Indications
Temporary cementation of crowns and bridges

Properties
  • Firm Retention / Easy Removal. No re-cementing temporaries.
  • Eugenol-Free
. Non-irritating to soft tissue / will not inhibit permanent cementation.
  • Fluoride Release
  • Potassium Nitrate - Known to reduce sensitivity and act as a sedative to the pulp.
  • Chlorhexidine - A proven anti-bacterial agent.
  • Resin-Matrix Formulation.
  • Good marginal seal with no washout.
  • Two-Stage Curing. Initial gel-set stabilizes temporary, allowing easy removal of excess.
  • Automix Syringe - Saves application time, guarantees consistent mix.
  • Neutral Shade - Blends esthetically with temporary restoration / No show-through.

 

  • Item # 100014
    Auto Mix - Intro
    1 Automix Syringe 5ml of Q-Temp
    10 Mix Tips
  • Item # 100015
    Auto Mix - Bulk
    4 Automix Syringe 5ml of Q-Temp
  • Item # 100010
    Hand Mix
    1 Syringe 10ml of Q-Temp Base
    1 Syringe 10ml of Q-Temp Catalyst
    1 Mixing Pad
    25 Mixing Spatulas

Flexural Strength

30 MPa

Film Thickness

10 μm

Solubility

7 μg/mm3

Water Sorption

22 μg/mm3

Linear Shrinkage

4.5 %

Exothermal Polymerization Temperature, Texo

31oC

Working Time @ 23oC

1.5 - 3.5 min

Initial Setting Time @ 37oC

1.5 - 2.0 min

Final Setting Time @ 37oC

3.0 - 4.0 min

Shelf Life

2 Years